Loading...

Product Details

PORTABLE SOIL & WATER ANALYSER KIT ( NU-344 )

Technical Specification

NU-344 A

NU-344 B

NU-344 C

NU-344 D

Microprocessor 8 Parameter

Microprocessor 7 Parameter

Microprocessor 6 Parameter

Microprocessor 5 Parameter

pH

pH

pH

pH

mV ( ORP )

mV ( ORP )

mV ( ORP )

mV ( ORP )

Cond. ( E.C. )

Cond. ( E.C. )

Cond. ( E.C. )

Cond. ( E.C. )

T.D.S.

T.D.S.

T.D.S.

T.D.S.

Temperature

Temperature

Temperature

Temperature

D.O.

D.O.

D.O.

D.O.

Salinity

Salinity

Salinity

Salinity

Turbidity

Turbidity

Turbidity

Turbidity

Complete in Brief Case, portable, Battery cum Mains operated with Rechargeable Battery.
Storage : 1000 Samples with Date & Time, Interface : RS-232 or USB
Error Indication : pH Error, buffer Error, ORP Error, Print Format : All Data - Date Wise          

ORP Electrode ( Platinum Electrode )
NOTE : ORP Electrode is optional for all the above models.

General        

Display : 16x2 Alphanumeric LCD, Operational Keys : Soft touch keys Power Supply: Mains cum Battery operated with rechargeable cell, at least 8 hours working after Single full recharge. Fitted in brief Case, Useful for field and as well as Laboratory use. Storage : 1000 Samples with Date & Time, Error Indication : pH Error, Buffer Error, ORP Error, PC Interface : RS-232, Real Time : 24 Hour Mode with Date. Print Format : All Data–Date Wise.

pH

Range : 0 to 14 pH, Resolution : 0.01 pH, Accuracy : 0.01 ± 1 Digit, Temp. Comp. : 0 to 100ºC Automatic (ATC), Slope Adjust.: 80% to 120% (Automatic), Auto pH Calibration : 5 points, Automatic 4.00, 7.00, 9.20, 10.50 & 12.45 pH

mV ( ORP )

Range : 0 to ± 1999.9 mV, Resolution : 1 mV , Accuracy : ± 0.1 mV ± 1 Digit

Conductivity 
   ( E.C. )

Range : 0-20, 0-200uS & 0-2mS, 0-20mS, 0-1000mS Auto Ranging, Resolution : 0.1 uS, Accuracy : ± 0.5% FS ± 1 Digit, Cell Constant : Adjustable, Temp. Co.-Eff. : Adjustable between 0 to 4%, Temp. Comp. : Automatic for entire range, Reference Temp : Selectable (5º to 50º C)

T.D.S.

Range : 0-20, 0-200 ppm & 0-2 ppt, 0-20 ppt, 0-1000 ppt Auto Ranging, Resolution : 0.1 ppm, Accuracy : ± 0.5% FS ± 1 Digit, Cell Const. : Adjustable, Temp. Co.-Eff. : Adjustable between 0 to 4%, Temp. Comp. : Automatic for entire range, Reference Temp : Selectable (5º to 50º C)

Salinity

Range : 0 to 50 ppt, Resolution : 0.1 ppt, Accuracy : ± 2% of Range ± 1 Digit

Temperature

Range : 0ºC to 200ºC, Resolution : 0.1ºC, Accuracy : ± 0.1ºC ± 1 Digit,
Sensor : RTD, PT100, Platinum Sensor

Dissolved 
   Oxygen

Range : 0 to 20 ppm, Resolution : 0.1 ppm, Accuracy : 0.1 ppm ± 1 Digit,
Temp. Comp.: Automatic , DO Sensor: Gold / Silver, Amperometric Probe

Turbidity / 
 Nephelometer

Range : 0 to 200, 1000 NTU / JTU, Resolution : 0.1, 1 NTU / JTU,
Accuracy : ± 1% FS ± 1 Digit, Sample System : 30 mm Clear Glass Test Tube